Efficient spiral in-out and EPI balanced steady-state free precession cine imaging using a high-performance 0.55T MRI.


ABSTRACT:

Purpose

Low-field MRI offers favorable physical properties for SNR-efficient long readout acquisitions such as spiral and EPI. We used a 0.55 tesla (T) MRI system equipped with high-performance hardware to increase the sampling duty cycle and extend the TR of balanced steady-state free precession (bSSFP) cardiac cine acquisitions, which typically are limited by banding artifacts.

Methods

We developed a high-efficiency spiral in-out bSSFP acquisition, with zeroth- and first-gradient moment nulling, and an EPI bSSFP acquisition for cardiac cine imaging using a contemporary MRI system modified to operate at 0.55T. Spiral in-out and EPI bSSFP cine protocols, with TR = 8 ms, were designed to maintain both spatiotemporal resolution and breath-hold length. Simulations, phantom imaging, and healthy volunteer imaging studies (n = 12) were performed to assess SNR and image quality using these high sampling duty-cycle bSSFP sequences.

Results

Spiral in-out bSSFP performed favorably at 0.55T and generated good image quality, whereas EPI bSSFP suffered motion and flow artifacts. There was no difference in ejection fraction comparing spiral in-out with standard Cartesian imaging. Moreover, human images demonstrated a 79% ± 21% increase in myocardial SNR using spiral in-out bSSFP and 50% ± 14% increase in SNR using EPI bSSFP as compared with the reference Cartesian acquisition. Spiral in-out acquisitions at 0.55T recovered 69% ± 14% of the myocardial SNR at 1.5T.

Conclusion

Efficient bSSFP spiral in-out provided high-quality cardiac cine imaging and SNR recovery on a high-performance 0.55T MRI system.

SUBMITTER: Restivo MC 

PROVIDER: S-EPMC7402011 | biostudies-literature | 2020 Nov

REPOSITORIES: biostudies-literature

altmetric image

Publications

Efficient spiral in-out and EPI balanced steady-state free precession cine imaging using a high-performance 0.55T MRI.

Restivo Matthew C MC   Ramasawmy Rajiv R   Bandettini W Patricia WP   Herzka Daniel A DA   Campbell-Washburn Adrienne E AE  

Magnetic resonance in medicine 20200414 5


<h4>Purpose</h4>Low-field MRI offers favorable physical properties for SNR-efficient long readout acquisitions such as spiral and EPI. We used a 0.55 tesla (T) MRI system equipped with high-performance hardware to increase the sampling duty cycle and extend the TR of balanced steady-state free precession (bSSFP) cardiac cine acquisitions, which typically are limited by banding artifacts.<h4>Methods</h4>We developed a high-efficiency spiral in-out bSSFP acquisition, with zeroth- and first-gradien  ...[more]

Similar Datasets

| S-EPMC11638602 | biostudies-literature
| S-EPMC11615597 | biostudies-literature
| S-EPMC11893024 | biostudies-literature
| S-EPMC4637255 | biostudies-literature
| S-EPMC10311259 | biostudies-literature
| S-EPMC9299476 | biostudies-literature
| S-EPMC10841523 | biostudies-literature
| S-EPMC11238270 | biostudies-literature
| S-EPMC4461545 | biostudies-literature
| S-EPMC6982567 | biostudies-literature