Serum creatinine/cystatin C ratio as a case-finding tool for low handgrip strength in Chinese middle-aged and older adults.
Ontology highlight
ABSTRACT: Measuring handgrip strength is the initial step to diagnose sarcopenia. To investigate whether the serum creatinine (Cr)/cystatin C (CysC) ratio could serve as a case-finding tool for low handgrip strength, we conducted a diagnostic accuracy study. Adults (aged ≥ 40 years) with normal renal function were recruited. Trained nurses collected blood samples and conducted the anthropometric measurements and handgrip strength test. The serum concentrations of Cr, CysC, and other biomarkers were measured. We recruited 1098 men and 1241 women. The Cr/CysC ratio was significantly associated with AWGS-defined low handgrip strength among men and women. The areas under the receiver operating characteristic curves were 0.79 among men and 0.78 among women for using the Cr/CysC ratio to identify AWGS-def
SUBMITTER: Tan L
PROVIDER: S-EPMC7441391 | biostudies-literature | 2020 Aug
REPOSITORIES: biostudies-literature
ACCESS DATA