A standardized nomenclature for spectrogram EEG patterns: Inter-rater agreement and correspondence with common intensive care unit EEG patterns.


ABSTRACT:

Objective

To determine the inter-rater agreement (IRA) of a standardized nomenclature for EEG spectrogram patterns, and to estimate the probability distribution of ictal-interictal continuum (IIC) patterns vs. other EEG patterns within each category in this nomenclature.

Methods

We defined seven spectrogram categories: "Solid Flames", "Irregular Flames", "Broadband-monotonous", "Narrowband-monotonous", "Stripes", "Low power", and "Artifact". Ten electroencephalographers scored 115 spectrograms and the corresponding raw EEG samples. Gwet's agreement coefficient was used to calculate IRA.

Results

Solid Flames represented seizures or IIC patterns 69.4% of the time. Irregular Flames represented seizures or IIC patterns 38.7% of the time. Broadband-monotonous primarily cor

SUBMITTER: Zafar SF 

PROVIDER: S-EPMC7461156 | biostudies-literature | 2020 Sep