Change in Dynamic Hyperinflation After Bronchoscopic Lung Volume Reduction in Patients with Emphysema.


ABSTRACT:

Background and purpose

In patients with severe emphysema, dynamic hyperinflation is superimposed on top of already existing static hyperinflation. Static hyperinflation reduces significantly after bronchoscopic lung volume reduction (BLVR). In this study, we investigated the effect of BLVR compared to standard of care (SoC) on dynamic hyperinflation.

Methods

Dynamic hyperinflation was induced by a manually paced tachypnea test (MPT) and was defined by change in inspiratory capacity (IC) measured before and after MPT. Static and dynamic hyperinflation measurements were performed both at baseline and 6 months after BLVR with endobronchial valves or coils (treatment group) or SoC (control group).

Results

Eighteen patients underwent BLVR (78% female, 57 (43-67) years, FEV1 25(18-37) %predicted, residual volume 231 (182-376) %predicted). Thirteen patients received SoC (100% female, 59 (44-74) years, FEV1 25 (19-37) %predicted, residual volume 225 (152-279) %predicted. The 6 months median change in dynamic hyperinflation in the treatment group was: + 225 ml (range - 113 to + 803) (p < 0.01) vs 0 ml (- 1067 to + 500) in the control group (p = 0.422). An increase in dynamic hyperinflation was significantly associated with a decrease in residual volume (r = - 0.439, p < 0.01).

Conclusion

Bronchoscopic lung volume reduction increases the ability for dynamic hyperinflation in patients with severe emphysema. We propose this is a consequence of improved static hyperinflation.

SUBMITTER: van Dijk M 

PROVIDER: S-EPMC7502448 | biostudies-literature | 2020 Oct

REPOSITORIES: biostudies-literature

altmetric image

Publications

Change in Dynamic Hyperinflation After Bronchoscopic Lung Volume Reduction in Patients with Emphysema.

van Dijk Marlies M   Klooster Karin K   Hartman Jorine E JE   Ten Hacken Nick H T NHT   Slebos Dirk-Jan DJ  

Lung 20200724 5


<h4>Background and purpose</h4>In patients with severe emphysema, dynamic hyperinflation is superimposed on top of already existing static hyperinflation. Static hyperinflation reduces significantly after bronchoscopic lung volume reduction (BLVR). In this study, we investigated the effect of BLVR compared to standard of care (SoC) on dynamic hyperinflation.<h4>Methods</h4>Dynamic hyperinflation was induced by a manually paced tachypnea test (MPT) and was defined by change in inspiratory capacit  ...[more]

Similar Datasets

| S-EPMC7004743 | biostudies-literature
| S-EPMC9932842 | biostudies-literature
| S-EPMC6390450 | biostudies-literature
| S-EPMC9677246 | biostudies-literature
| S-EPMC4524390 | biostudies-literature
| S-EPMC4321042 | biostudies-literature
| S-EPMC10601098 | biostudies-literature
| S-EPMC7723581 | biostudies-literature
| S-EPMC5300131 | biostudies-literature
| S-EPMC9233031 | biostudies-literature