Organic Field-Effect Transistors as Flexible, Tissue-Equivalent Radiation Dosimeters in Medical Applications.


ABSTRACT: Radiation therapy is one of the most prevalent procedures for cancer treatment, but the risks of malignancies induced by peripheral beam in healthy tissues surrounding the target is high. Therefore, being able to accurately measure the exposure dose is a critical aspect of patient care. Here a radiation detector based on an organic field-effect transistor (RAD-OFET) is introduced, an in vivo dosimeter that can be placed directly on a patient's skin to validate in real time the dose being delivered and ensure that for nearby regions an acceptable level of low dose is being received. This device reduces the errors faced by current technologies in approximating the dose profile in a patient's body, is sensitive for doses relevant to radiation treatment procedures, and robust when incorporated into conformal large-area electronics. A model is proposed to describe the operation of RAD-OFETs, based on the interplay between charge photogeneration and trapping.

SUBMITTER: Zeidell AM 

PROVIDER: S-EPMC7509662 | biostudies-literature | 2020 Sep

REPOSITORIES: biostudies-literature

altmetric image

Publications

Organic Field-Effect Transistors as Flexible, Tissue-Equivalent Radiation Dosimeters in Medical Applications.

Zeidell Andrew M AM   Ren Tong T   Filston David S DS   Iqbal Hamna F HF   Holland Emma E   Bourland J Daniel JD   Anthony John E JE   Jurchescu Oana D OD  

Advanced science (Weinheim, Baden-Wurttemberg, Germany) 20200730 18


Radiation therapy is one of the most prevalent procedures for cancer treatment, but the risks of malignancies induced by peripheral beam in healthy tissues surrounding the target is high. Therefore, being able to accurately measure the exposure dose is a critical aspect of patient care. Here a radiation detector based on an organic field-effect transistor (RAD-OFET) is introduced, an in vivo dosimeter that can be placed directly on a patient's skin to validate in real time the dose being deliver  ...[more]

Similar Datasets

| S-EPMC454198 | biostudies-other
| S-EPMC6145259 | biostudies-literature
| S-EPMC8678985 | biostudies-literature
| S-EPMC10264417 | biostudies-literature
| S-EPMC9259716 | biostudies-literature
| S-EPMC5966445 | biostudies-literature
| S-EPMC9839865 | biostudies-literature
| S-EPMC7153480 | biostudies-literature
| S-EPMC9906658 | biostudies-literature
| S-EPMC7314562 | biostudies-literature