Unknown

Dataset Information

0

3D Versus 4K Display System - Influence of "State-of-the-art"-Display Technique on Surgical Performance (IDOSP-study) in Minimally Invasive Surgery: A Randomized Cross-over Trial.


ABSTRACT: OBJECTIVE:To evaluate if "state-of-the-art" 3D- versus 4K-display techniques could influence surgical performance. BACKGROUND:High quality minimally invasive surgery is challenging. Therefore excellent vision is crucial. 3D display technique (3D) and 2D-4K technique (4K) are designed to facilitate surgical performance, either due to spatial resolution (3D) or due to very high resolution (4K). METHODS:In randomized cross-over trial the surgical performance of medical students (MS), non-board certified surgeons (NBC), and board certified surgeons (BC) was compared using 3D versus 4K display technique at a minimally invasive training Parkour. RESULTS:One hundred twenty-eight participants were included (February 2018 through October 2019, 49 MS, 39 NBC, 40 BC). The overall Parkour time (s) 3D versus 4K was 712.5 s ± 17.5?s versus 999.5 s?±?25.1?s (P < 0.001) for all levels of experience. It was (3D vs 4K) for MS (30 tasks) 555.4 s?±?28.9?s versus 858.7 s?±?41.6?s, (P < 0.0001), for NBC (42 tasks) 935.9 s?±?31.5?s versus 1274.1 s?±?45.1?s (P?=< 0.001) and for BC (42 task) 646.3 s?±?30.9?s versus 865.7 s?±?43.7?s (P < 0.001). The overall number of mistakes was (3D vs 4K) 10.0?±?0.5 versus 13.3?±?0.7 (P < 0.001), for MS 8.9?±?0.9 versus 13.1?±?1.1 (P < 0.001), for NBC 12.45?±?1.0 versus 16.7?±?1.2 (P < 0.001) and for BC 8.8?±?1.0 versus 10.0?±?1.2 (P = 0.18). MS, BC, and NBC showed shorter performance time in 100% of the task with 3D (significantly in 6/7 tasks). For number of mistakes the effect was less pronounced for more experienced surgeons. The National Aeronautics and Space Administration-task load index was lower with 3D. CONCLUSION:3D laparoscopic display technique optimizes surgical performance compared to the 4K technique. Surgeons benefit from the improved visualization regardless of their individual surgical expertise.

SUBMITTER: Wahba R 

PROVIDER: S-EPMC7553197 | biostudies-literature | 2020 Nov

REPOSITORIES: biostudies-literature

altmetric image

Publications

3D Versus 4K Display System - Influence of "State-of-the-art"-Display Technique on Surgical Performance (IDOSP-study) in Minimally Invasive Surgery: A Randomized Cross-over Trial.

Wahba Roger R   Datta Rabi R   Bußhoff Jana J   Bruns Thomas T   Hedergott Andrea A   Gietzelt Caroline C   Dieplinger Georg G   Fuchs Hans H   Morgenstern Bernd B   Möller Desdemona D   Hellmich Martin M   Bruns Christiane J CJ   Stippel Dirk L DL  

Annals of surgery 20201101 5


<h4>Objective</h4>To evaluate if "state-of-the-art" 3D- versus 4K-display techniques could influence surgical performance.<h4>Background</h4>High quality minimally invasive surgery is challenging. Therefore excellent vision is crucial. 3D display technique (3D) and 2D-4K technique (4K) are designed to facilitate surgical performance, either due to spatial resolution (3D) or due to very high resolution (4K).<h4>Methods</h4>In randomized cross-over trial the surgical performance of medical student  ...[more]

Similar Datasets

| S-EPMC6540550 | biostudies-literature
| S-EPMC6678699 | biostudies-literature
| S-EPMC5639027 | biostudies-literature
| S-EPMC7108992 | biostudies-literature
| S-EPMC9793183 | biostudies-literature
| S-EPMC5178372 | biostudies-literature
| S-EPMC5448728 | biostudies-other
| S-EPMC3764292 | biostudies-literature
| S-EPMC11475372 | biostudies-literature
| S-EPMC6830494 | biostudies-literature