Unknown

Dataset Information

0

Infrared Multiphoton Dissociation Enables Top-Down Characterization of Membrane Protein Complexes and G Protein-Coupled Receptors.


ABSTRACT: Membrane proteins are challenging to analyze by native mass spectrometry (MS) as their hydrophobic nature typically requires stabilization in detergent micelles that are removed prior to analysis via collisional activation. There is however a practical limit to the amount of energy which can be applied, which often precludes subsequent characterization by top-down MS. To overcome this barrier, we have applied a modified Orbitrap Eclipse Tribrid mass spectrometer coupled to an infrared laser within a high-pressure linear ion trap. We show how tuning the intensity and time of incident photons enables liberation of membrane proteins from detergent micelles. Specifically, we relate the ease of micelle removal to the infrared absorption of detergents in both condensed and gas phases. Top-down MS via infrared multiphoton dissociation (IRMPD), results in good sequence coverage enabling unambiguous identification of membrane proteins and their complexes. By contrasting and comparing the fragmentation patterns of the ammonia channel with two class A GPCRs, we identify successive cleavage of adjacent amino acids within transmembrane domains. Using gas-phase molecular dynamics simulations, we show that areas prone to fragmentation maintain aspects of protein structure at increasing temperatures. Altogether, we propose a rationale to explain why and where in the protein fragment ions are generated.

SUBMITTER: Lutomski CA 

PROVIDER: S-EPMC7615181 | biostudies-literature | 2023 Sep

REPOSITORIES: biostudies-literature

altmetric image

Publications

Infrared Multiphoton Dissociation Enables Top-Down Characterization of Membrane Protein Complexes and G Protein-Coupled Receptors.

Lutomski Corinne A CA   El-Baba Tarick J TJ   Hinkle Joshua D JD   Liko Idlir I   Bennett Jack L JL   Kalmankar Neha V NV   Dolan Andrew A   Kirschbaum Carla C   Greis Kim K   Urner Leonhard H LH   Kapoor Parth P   Yen Hsin-Yung HY   Pagel Kevin K   Mullen Christopher C   Syka John E P JEP   Robinson Carol V CV  

Angewandte Chemie (International ed. in English) 20230725 36


Membrane proteins are challenging to analyze by native mass spectrometry (MS) as their hydrophobic nature typically requires stabilization in detergent micelles that are removed prior to analysis via collisional activation. There is however a practical limit to the amount of energy which can be applied, which often precludes subsequent characterization by top-down MS. To overcome this barrier, we have applied a modified Orbitrap Eclipse Tribrid mass spectrometer coupled to an infrared laser with  ...[more]

Similar Datasets

| S-EPMC5555583 | biostudies-literature
| S-EPMC5031736 | biostudies-literature
| S-EPMC5726920 | biostudies-literature
| S-EPMC7485267 | biostudies-literature