Performance of a lymphocyte t interferon gamma test (Quantiferon-TB gold in tube) in the diagnosis of active tuberculosis in HIV-infected children.


ABSTRACT:

Objective

Evaluate the performance of QuantiFERON ® -TB Gold In-Tube test (QFT-GIT), to improve the diagnosis of active tuberculosis (TB) in Human Immuno-Deficiency Virus (HIV)-infected children.

Method

Sensitivity, specificity, Positive Predictive Value (PPV), Negative Predictive Value (NPV) of QFT-GIT were assessed in 58/63 HIV-infected children who were suspected of having TB.

Results

Sensitivity of QFT-GIT was 20.69%, specificity 96.55%, PPV/NPV respectively 85.71% and 54.90%.

Conclusion

QFT-GIT appears to be of little contribution to the diagnosis of active TB in children living with HIV in a TB-endemic country.