ABSTRACT: Background
Iatrogenic perforation of the right ventricle (RV) is a rare but recognized complication of pericardiocentesis. Treatment strategies for RV perforation include surgical repair and percutaneous closure. In this case report, we describe the use of an angio-seal vascular closure device (Terumo Interventional Systems) to seal an iatrogenic RV perforation secondary to incorrect placement of a pericardial drain.Case summary
A 55-year-old female presented with an anterior ST-elevation myocardial infarction. Coronary angiography demonstrated occlusion of the left anterior descending artery. The patient went on to have primary percutaneous coronary intervention and both the left anterior descending and D1 were wired. During kissing balloon inflation, the Sion Blue wire mi