Placing a lumen-apposing metal stent despite ascites: feasibility and safety.


ABSTRACT:

Background and aims

Placing a lumen-apposing metal stent (LAMS) through ascites carries serious risks, including death from leakage around the LAMS and failure to create a mature fistula between the 2 lumens. However, sometimes no options exist or are equally dangerous. We present 5 patients who underwent LAMS placement despite ascites in 2 different locations.

Methods

This is a retrospective review of 5 patients who underwent LAMS placement despite ascites in 2 different locations from 2016 to 2018.

Results

Three patients with cholecystitis and 2 patients with afferent limb syndrome and severe ascites were treated with a combination of preprocedural and intraprocedural paracentesis. Serum ascites albumin gradient was measured. Weight was recorded daily. Patients were encouraged to sleep at an incline, and periodic paracentesis (every 3-7 days) was performed when ascites reaccumulated over 4 weeks. Median volume of ascites aspirated was 2 L preprocedurally and 300 mL intraprocedurally. Only 1 patient had ascites with a high serum ascites albumin gradient and was treated with diuretics. Technical and clinical success was achieved in all 5 patients without any adverse events over a median follow-up of 28 weeks.

Conclusions

In situations in which no better options remain, LAMS placement appears to be safe after adequate and aggressive treatment of the underlying ascites pre-, intra-, and postprocedurally. Larger studies are needed to establish the safety of this approach.

SUBMITTER: Irani S 

PROVIDER: S-EPMC7652702 | biostudies-literature | 2020 Nov

REPOSITORIES: biostudies-literature

altmetric image

Publications

Placing a lumen-apposing metal stent despite ascites: feasibility and safety.

Irani Shayan S  

VideoGIE : an official video journal of the American Society for Gastrointestinal Endoscopy 20200821 11


<h4>Background and aims</h4>Placing a lumen-apposing metal stent (LAMS) through ascites carries serious risks, including death from leakage around the LAMS and failure to create a mature fistula between the 2 lumens. However, sometimes no options exist or are equally dangerous. We present 5 patients who underwent LAMS placement despite ascites in 2 different locations.<h4>Methods</h4>This is a retrospective review of 5 patients who underwent LAMS placement despite ascites in 2 different location  ...[more]

Similar Datasets

| S-EPMC5991652 | biostudies-literature
| S-EPMC6004339 | biostudies-literature
| S-EPMC9669637 | biostudies-literature
| S-EPMC7570442 | biostudies-literature
| S-EPMC10751451 | biostudies-literature
| S-EPMC5990990 | biostudies-literature
| S-EPMC7572616 | biostudies-literature
| S-EPMC6408707 | biostudies-literature
| S-EPMC9902685 | biostudies-literature
| S-EPMC10305248 | biostudies-literature