Unknown

Dataset Information

Initial evidence of a 50% reduction of contrast media using digital variance angiography in endovascular carotid interventions.


ABSTRACT:

Purpose

In previous clinical studies Digital Variance Angiography (DVA) provided higher signal-to-noise ratio (SNR) and better image quality than Digital Subtraction Angiography (DSA). Our aim was to investigate whether this quality reserve of DVA provides an opportunity for the reduction of iodinated contrast media (ICM) in carotid X-ray angiography (CXA).

Method

Our prospective study enrolled 26 patients (67.0 ± 8.1 years) undergoing carotid percutaneous transluminal angioplasty. The SNR of DSA and DVA image pairs obtained by a standard (100 %, 6 mL ICM) or a low-dose (50 %, 3 mL ICM) protocol were compared. Visual evaluation of all images was performed by five specialists using a 5-grade rating scale. The quality of DSA100 and DVA50 videos was also c

SUBMITTER: Orias VI 

PROVIDER: S-EPMC7683322 | biostudies-literature | 2020

REPOSITORIES: biostudies-literature