Three-Dimensional Paper-Based Microfluidic Analysis Device for Simultaneous Detection of Multiple Biomarkers with a Smartphone.


ABSTRACT: Paper-based microfluidic analysis devices (μPADs) have attracted attention as a cost-effective platform for point-of-care testing (POCT), food safety, and environmental monitoring. Recently, three-dimensional (3D)-μPADs have been developed to improve the performance of μPADs. For accurate diagnosis of diseases, however, 3D-μPADs need to be developed to simultaneously detect multiple biomarkers. Here, we report a 3D-μPADs platform for the detection of multiple biomarkers that can be analyzed and diagnosed with a smartphone. The 3D-μPADs were fabricated using a 3D digital light processing printer and consisted of a sample reservoir (300 µL) connected to 24 detection zones (of 4 mm in diameter) through eight microchannels (of 2 mm in width). With the smartphone application, eight different biomarkers related to various diseases were detectable in concentrations ranging from normal to abnormal conditions: glucose (0-20 mmol/L), cholesterol (0-10 mmol/L), albumin (0-7 g/dL), alkaline phosphatase (0-800 U/L), creatinine (0-500 µmol/L), aspartate aminotransferase (0-800 U/L), alanine aminotransferase (0-1000 U/L), and urea nitrogen (0-7.2 mmol/L). These results suggest that 3D-µPADs can be used as a POCT platform for simultaneous detection of multiple biomarkers.

SUBMITTER: Baek SH 

PROVIDER: S-EPMC7700338 | biostudies-literature | 2020 Nov

REPOSITORIES: biostudies-literature

altmetric image

Publications

Three-Dimensional Paper-Based Microfluidic Analysis Device for Simultaneous Detection of Multiple Biomarkers with a Smartphone.

Baek Seung Ho SH   Park Chanyong C   Jeon Jaehyung J   Park Sungsu S  

Biosensors 20201121 11


Paper-based microfluidic analysis devices (μPADs) have attracted attention as a cost-effective platform for point-of-care testing (POCT), food safety, and environmental monitoring. Recently, three-dimensional (3D)-μPADs have been developed to improve the performance of μPADs. For accurate diagnosis of diseases, however, 3D-μPADs need to be developed to simultaneously detect multiple biomarkers. Here, we report a 3D-μPADs platform for the detection of multiple biomarkers that can be analyzed and  ...[more]

Similar Datasets

| S-EPMC8615519 | biostudies-literature
| S-EPMC9730490 | biostudies-literature
| S-EPMC11430598 | biostudies-literature
| S-EPMC9060762 | biostudies-literature
| S-EPMC4960536 | biostudies-literature
| S-EPMC6814273 | biostudies-literature
| S-EPMC2604941 | biostudies-literature
| S-EPMC9142996 | biostudies-literature
| S-EPMC4985622 | biostudies-literature
| S-EPMC10377552 | biostudies-literature