Test-retest repeatability of [18F]Flortaucipir PET in Alzheimer's disease and cognitively normal individuals.


ABSTRACT: The aim of this study was to investigate the test-retest (TRT) repeatability of various parametric quantification methods for [18F]Flortaucipir positron emission tomography (PET). We included eight subjects with dementia or mild cognitive impairment due to Alzheimer's disease and six cognitively normal subjects. All underwent two 130-min dynamic [18F]Flortaucipir PET scans within 3 ± 1 weeks. Data were analyzed using reference region models receptor parametric mapping (RPM), simplified reference tissue method 2 (SRTM2) and reference logan (RLogan), as well as standardized uptake value ratios (SUVr, time intervals 40-60, 80-100 and 110-130 min post-injection) with cerebellar gray matter as reference region. We obtained distribution volume ratio or SUVr, first for all brain regions and then in three tau-specific regions-of-interest (ROIs). TRT repeatability (%) was defined as |retest-test|/(average (test + retest)) × 100. For all methods and across ROIs, TRT repeatability ranged from (median (IQR)) 0.84% (0.68-2.15) to 6.84% (2.99-11.50). TRT repeatability was good for all reference methods used, although semi-quantitative models (i.e. SUVr) performed marginally worse than quantitative models, for instance TRT repeatability of RPM: 1.98% (0.78-3.58) vs. SUVr80-100: 3.05% (1.28-5.52), p < 0.001. Furthermore, for SUVr80-100 and SUVr110-130, with higher average SUVr, more variation was observed. In conclusion, while TRT repeatability was good for all models used, quantitative methods performed slightly better than semi-quantitative methods.

SUBMITTER: Timmers T 

PROVIDER: S-EPMC7705644 | biostudies-literature | 2020 Dec

REPOSITORIES: biostudies-literature

altmetric image

Publications

Test-retest repeatability of [<sup>18</sup>F]Flortaucipir PET in Alzheimer's disease and cognitively normal individuals.

Timmers Tessa T   Ossenkoppele Rik R   Visser Denise D   Tuncel Hayel H   Wolters Emma E EE   Verfaillie Sander Cj SC   van der Flier Wiesje M WM   Boellaard Ronald R   Golla Sandeep Sv SS   van Berckel Bart Nm BN  

Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism 20191001 12


The aim of this study was to investigate the test-retest (TRT) repeatability of various parametric quantification methods for [<sup>18</sup>F]Flortaucipir positron emission tomography (PET). We included eight subjects with dementia or mild cognitive impairment due to Alzheimer's disease and six cognitively normal subjects. All underwent two 130-min dynamic [<sup>18</sup>F]Flortaucipir PET scans within 3 ± 1 weeks. Data were analyzed using reference region models receptor parametric mapping (RPM)  ...[more]

Similar Datasets

| S-EPMC7044757 | biostudies-literature
| S-EPMC8786991 | biostudies-literature
| S-EPMC11208353 | biostudies-literature
| S-EPMC8138337 | biostudies-literature
| S-EPMC5565786 | biostudies-literature
| S-EPMC5966478 | biostudies-literature
| S-EPMC7365267 | biostudies-literature
| S-EPMC8255216 | biostudies-literature
| S-EPMC6357510 | biostudies-literature
| S-EPMC7466905 | biostudies-literature