Corneal thickness evaluation in healthy eyes: Comparison between two different Scheimpflug devices.


ABSTRACT:

Purpose

To evaluate the correlation between corneal thickness (CT) measurements obtained with two Scheimpflug devices, Pentacam HR and Precisio, and to elaborate, if necessary, a regression formula which could make these results comparable.

Design

Retrospective, Comparative, Observational study.

Setting

Department of Medicine, Surgery and Dentistry, "Scuola Medica Salernitana" University of Salerno, Italy.

Methods

One hundred twenty four healthy eyes of 124 volunteers (65 males; range: 20-32 years; mean age of 24.8 ± 1.7) were included in this study. CT was measured using Pentacam HR and Precisio in three different points: the pupil center (PC), the corneal apex (CA) and the thinnest point (TP).

Results

CT obtained with both devices at the PC, at the CA