Ontology highlight
ABSTRACT: Objectives
This prospective, observational, non-randomized multicentric study was conducted to compare efficiency and toxicity using different modalities of stereotactic body radiation therapy (SBRT) in early-stage peripheral non-small cell lung cancer (NSCLC).Methods
From 9 April to 11 December, 106 patients were treated according to the local equipment availability for peripheral NSCLC with SBRT: 68 by linear accelerator equipped for SBRT and 38 by Cyberknife®. Multivariate analysis and propensity score analysis using Inverse Probability Treatment Weighting (IPTW) were undertaken in an effort to adjust for potential bias due to non-randomization.Results
2-year local control rates were 97.0% (95% CI: [90.6%; 99.4%]) with SBRT by Linac vs 100% (95%
SUBMITTER: Claude L
PROVIDER: S-EPMC7716015 | biostudies-literature | 2020 Dec
REPOSITORIES: biostudies-literature