Unknown

Dataset Information

0

Dynamic distortion correction for functional MRI using FID navigators.


ABSTRACT:

Purpose

To develop a method for slice-wise dynamic distortion correction for EPI using rapid spatiotemporal B0 field measurements from FID navigators (FIDnavs) and to evaluate the efficacy of this new approach relative to an established data-driven technique.

Methods

A low-resolution reference image was used to create a forward model of FIDnav signal changes to enable estimation of spatiotemporal B0 inhomogeneity variations up to second order from measured FIDnavs. Five volunteers were scanned at 3 T using a 64-channel coil with FID-navigated EPI. The accuracy of voxel shift measurements and geometric distortion correction was assessed for experimentally induced magnetic field perturbations. The temporal SNR was evaluated in EPI time-series acquired at rest and with a continuous nose-touching action, before and after image realignment.

Results

Field inhomogeneity coefficients and voxel shift maps measured using FIDnavs were in excellent agreement with multi-echo EPI measurements. The FID-navigated distortion correction accurately corrected image geometry in the presence of induced magnetic field perturbations, outperforming the data-driven approach in regions with large field offsets. In functional MRI scans with nose touching, FIDnav-based correction yielded temporal SNR gains of 30% in gray matter. Following image realignment, which accounted for global image shifts, temporal SNR gains of 3% were achieved.

Conclusions

Our proposed application of FIDnavs enables slice-wise dynamic distortion correction with high temporal efficiency. We achieved improved signal stability by leveraging the encoding information from multichannel coils. This approach can be easily adapted to other EPI-based sequences to improve temporal SNR for a variety of clinical and research applications.

SUBMITTER: Wallace TE 

PROVIDER: S-EPMC7718422 | biostudies-literature | 2021 Mar

REPOSITORIES: biostudies-literature

altmetric image

Publications

Dynamic distortion correction for functional MRI using FID navigators.

Wallace Tess E TE   Polimeni Jonathan R JR   Stockmann Jason P JP   Hoge W Scott WS   Kober Tobias T   Warfield Simon K SK   Afacan Onur O  

Magnetic resonance in medicine 20200924 3


<h4>Purpose</h4>To develop a method for slice-wise dynamic distortion correction for EPI using rapid spatiotemporal B<sub>0</sub> field measurements from FID navigators (FIDnavs) and to evaluate the efficacy of this new approach relative to an established data-driven technique.<h4>Methods</h4>A low-resolution reference image was used to create a forward model of FIDnav signal changes to enable estimation of spatiotemporal B<sub>0</sub> inhomogeneity variations up to second order from measured FI  ...[more]

Similar Datasets

| S-EPMC9670860 | biostudies-literature
| S-EPMC6258267 | biostudies-literature
| S-EPMC10705259 | biostudies-literature
| S-EPMC9529812 | biostudies-literature
| S-EPMC6824939 | biostudies-literature
| S-EPMC3320676 | biostudies-other
| S-EPMC6524807 | biostudies-literature
| S-EPMC7065144 | biostudies-literature
| S-EPMC10106483 | biostudies-literature
| S-EPMC9177803 | biostudies-literature