ABSTRACT: Objective
We aimed to establish a quantitative description of motion patterns and establish test-retest reliability of the four-dimensional CT when quantifying in vivo kinematics of the scaphoid, lunate, and capitate.Materials and methods
We assessed in vivo kinematics of both wrists of 20 healthy volunteers (11 men and 9 women) between the ages of 20 and 40 years. All volunteers performed active flexion-extension and radial-ulnar deviation with both wrists. To test for reliability, one motion cycle was rescanned for both wrists approximately 15 min after the first scan. The coefficient of multiple correlation was used to analyze reliability. When two motion patterns are similar, the coefficient of multiple correlation tends towards 1, whereas in dissimilar motion patterns,