Unknown

Dataset Information

Quantitative and simultaneous measurement of oxygen consumption rates in rat brain and skeletal muscle using 17 O MRS imaging at 16.4T.


ABSTRACT:

Purpose

Oxygen-17 (17 O) MRS imaging, successfully used in the brain, is extended by imaging the oxygen metabolic rate in the resting skeletal muscle and used to determine the total whole-body oxygen metabolic rate in the rat.

Methods

During and after inhalations of 17 O2 gas, dynamic 17 O MRSI was performed in rats (n = 8) ventilated with N2 O or N2 at 16.4 T. Time courses of the H217 O concentration from regions of interest located in brain and muscle tissue were examined and used to fit an animal-adapted 3-phase metabolic model of oxygen consumption. CBF was determined with an independent washout method. Finally, body oxygen metabolic rate was calculated using a global steady-state app

SUBMITTER: Wiesner HM 

PROVIDER: S-EPMC7775343 | biostudies-literature | 2021 Apr