Ontology highlight
ABSTRACT:
SUBMITTER: Jaarsma-Coes MG
PROVIDER: S-EPMC7807689 | biostudies-literature | 2020 Oct
REPOSITORIES: biostudies-literature
Jaarsma-Coes Myriam G MG Marinkovic Marina M Astreinidou Eleftheria E Schuurmans Megan S MS Peters Femke P FP Luyten Gregorius P M GPM Rasch Coen R N CRN Beenakker Jan-Willem M JM
Physics and imaging in radiation oncology 20201006
Proton beam therapy (PBT) for uveal melanoma (UM) is performed in sitting position, while the acquisition of the Magnetic resonance (MR)-images for treatment planning is performed in supine position. We assessed the effect of this difference in position on the eye- and tumour- shape. Seven subjects and six UM-patients were scanned in supine and a seating mimicking position. The distances between the tumour/sclera in both positions were calculated. The median distance between both positions was 0 ...[more]