Unknown

Dataset Information

0

Design of Electro-Thermal Glove with Sensor Function for Raynaud's Phenomenon Patients.


ABSTRACT: Raynaud's phenomenon (RP) is a disease that mainly affects human fingertips during cold weather. It is difficult to treat this disease using medicine, apart from keeping the body in a warm environment. In this research, conductive knitted fabrics were fabricated to help relax the vessels of the patient's fingertips by providing proper heat, and also serving as a sensor to detect finger motion after relaxation of the blood vessels of patients. Four different structures, termed plain, purl, interlock, and rib were produced using conductive silver/PE (polyethylene) yarn and wool yarn, with a computerized flat knitting machine. The effect of knitted structure on the electro-thermal behavior, sensitivity, and stability of resistance change (∆R/R) under different tensile forces was investigated. By comprehensive comparison, the purl structure was identified as the preferred structure for the heating glove for RP patients, owing to superior electro-thermal behavior. Additionally, the purl structure had a greater capacity to detect different motions with stable resistance change. This potential electro-thermal glove could be used for functional, as well as aesthetic (fashion) purposes, and could be worn at any time and occasion with complete comfort.

SUBMITTER: Dawit H 

PROVIDER: S-EPMC7828797 | biostudies-literature | 2021 Jan

REPOSITORIES: biostudies-literature

altmetric image

Publications

Design of Electro-Thermal Glove with Sensor Function for Raynaud's Phenomenon Patients.

Dawit Hewan H   Zhang Qian Q   Li Yimeng Y   Islam Syed Rashedul SR   Mao Jifu J   Wang Lu L  

Materials (Basel, Switzerland) 20210114 2


Raynaud's phenomenon (RP) is a disease that mainly affects human fingertips during cold weather. It is difficult to treat this disease using medicine, apart from keeping the body in a warm environment. In this research, conductive knitted fabrics were fabricated to help relax the vessels of the patient's fingertips by providing proper heat, and also serving as a sensor to detect finger motion after relaxation of the blood vessels of patients. Four different structures, termed plain, purl, interl  ...[more]

Similar Datasets

| S-EPMC8127538 | biostudies-literature
| S-EPMC6718219 | biostudies-literature
| S-EPMC2856576 | biostudies-literature
| S-EPMC12923405 | biostudies-literature
| S-EPMC8220350 | biostudies-literature
| S-EPMC8922649 | biostudies-literature
| S-EPMC8003729 | biostudies-literature
| S-EPMC6138507 | biostudies-literature
| S-EPMC10570309 | biostudies-literature