Unknown

Dataset Information

0

Direct diagnostic testing of SARS-CoV-2 without the need for prior RNA extraction.


ABSTRACT: The COVID-19 pandemic has resulted in an urgent need for a rapid, point of care diagnostic testing that could be rapidly scaled on a worldwide level. We developed and tested a highly sensitive and robust assay based on reverse transcription loop mediated isothermal amplification (RT-LAMP) that uses readily available reagents and a simple heat block using contrived spike-in and actual clinical samples. RT-LAMP testing on RNA-spiked samples showed a limit of detection (LoD) of 2.5 copies/μl of viral transport media. RT-LAMP testing directly on clinical nasopharyngeal swab samples in viral transport media had an 85% positive percentage agreement (PPA) (17/20), and 100% negative percentage agreement (NPV) and delivered results in 30 min. Our optimized RT-LAMP based testing method is a scalable system that is sufficiently sensitive and robust to test for SARS-CoV-2 directly on clinical nasopharyngeal swab samples in viral transport media in 30 min at the point of care without the need for specialized or proprietary equipment or reagents. This cost-effective and efficient one-step testing method can be readily available for COVID-19 testing world-wide, especially in resource poor settings.

SUBMITTER: Wei S 

PROVIDER: S-EPMC7844049 | biostudies-literature | 2021 Jan

REPOSITORIES: biostudies-literature

altmetric image

Publications

Direct diagnostic testing of SARS-CoV-2 without the need for prior RNA extraction.

Wei Shan S   Kohl Esther E   Djandji Alexandre A   Morgan Stephanie S   Whittier Susan S   Mansukhani Mahesh M   Hod Eldad E   D'Alton Mary M   Suh Yousin Y   Williams Zev Z  

Scientific reports 20210128 1


The COVID-19 pandemic has resulted in an urgent need for a rapid, point of care diagnostic testing that could be rapidly scaled on a worldwide level. We developed and tested a highly sensitive and robust assay based on reverse transcription loop mediated isothermal amplification (RT-LAMP) that uses readily available reagents and a simple heat block using contrived spike-in and actual clinical samples. RT-LAMP testing on RNA-spiked samples showed a limit of detection (LoD) of 2.5 copies/μl of vir  ...[more]

Similar Datasets

| S-EPMC7480275 | biostudies-literature
| S-EPMC7380591 | biostudies-literature
| S-EPMC7556528 | biostudies-literature
| S-EPMC7239058 | biostudies-literature
| S-EPMC7349311 | biostudies-literature
| S-EPMC7459950 | biostudies-literature
| S-EPMC10165292 | biostudies-literature
| S-EPMC9217698 | biostudies-literature
| S-EPMC8820190 | biostudies-literature
| S-EPMC7593567 | biostudies-literature