Unknown

Dataset Information

0

Micromolded Carbon Paste Microelectrodes for Electrogenerated Chemiluminescent Detection on Microfluidic Devices.


ABSTRACT: Micromolded carbon paste electrodes are easily fabricated, disposable, and can be integrated into microfluidic devices to fabricate inexpensive sensors and biosensors. In this work, carbon paste microelectrodes were fabricated in poly(dimethylsiloxane) using micromolding techniques and were coupled to a microfluidic channel to fabricate electrogenerated chemiluminescent (ECL) sensors. ECL was generated using both the tris(2,2'-bipyridyl)ruthenium(II)-tripropylamine system and the hydrogen peroxide and luminol system. For each of these ECL systems, the sensor fabrication method was optimized, along with key experimental parameters (applied voltage, solution flow rate, buffer species and luminol concentration). The limit of detection (S/N = 3) for TPrA was ~2.4 μM with a linear range of 10-100μM. For hydrogen peroxide the LOD was ~11 μM and the electrodes gave a linear response between 30 μM and 200 μM hydrogen peroxide. Electrodes containing glucose oxidase were fabricated using this new method, demonstrating that glucose could be indirectly detected via generation of hydrogen peroxide by the enzymatic reaction at the micromolded biosensor.

SUBMITTER: Gross EM 

PROVIDER: S-EPMC7853645 | biostudies-literature | 2020 Aug

REPOSITORIES: biostudies-literature

altmetric image

Publications

Micromolded Carbon Paste Microelectrodes for Electrogenerated Chemiluminescent Detection on Microfluidic Devices.

Gross Erin M EM   Porter Laura R LR   Stukel Nicholas R NR   Lowry Emily R ER   Schaffer Leah V LV   Maddipati Sai Sujana SS   Hoyt Dylan J DJ   Stombaugh Sarah E SE   Peila Sarah R SR   Henry Charles S CS  

ChemElectroChem 20200507 15


Micromolded carbon paste electrodes are easily fabricated, disposable, and can be integrated into microfluidic devices to fabricate inexpensive sensors and biosensors. In this work, carbon paste microelectrodes were fabricated in poly(dimethylsiloxane) using micromolding techniques and were coupled to a microfluidic channel to fabricate electrogenerated chemiluminescent (ECL) sensors. ECL was generated using both the tris(2,2'-bipyridyl)ruthenium(II)-tripropylamine system and the hydrogen peroxi  ...[more]

Similar Datasets

| S-EPMC6317378 | biostudies-literature
| S-EPMC9531868 | biostudies-literature
| S-EPMC8557186 | biostudies-literature
| S-EPMC3804350 | biostudies-literature
| S-EPMC9048710 | biostudies-literature
| S-EPMC4972099 | biostudies-literature
| S-EPMC3392196 | biostudies-literature
| S-EPMC4718531 | biostudies-literature
| S-EPMC8168831 | biostudies-literature
| S-EPMC4067008 | biostudies-literature