Unknown

Dataset Information

Controlled sequential elevation of the head and thorax combined with active compression decompression cardiopulmonary resuscitation and an impedance threshold device improves neurological survival in a porcine model of cardiac arrest.


ABSTRACT:

Aim of the study

Controlled sequential elevation of the head and thorax (CSE) during active compression decompression (ACD) cardiopulmonary resuscitation (CPR) with an impedance threshold device (ITD) has been shown to increase cerebral perfusion pressure and cerebral blood flow in previous animal studies as compared to the traditional supine position. The potential for this novel bundled treatment strategy to improve survival with intact neurological function is unknown.

Methods

Female farm pigs were sedated, intubated, and anesthetized. Central arterial and venous access were continuously monitored. Regional brain tissue perfusion (CerO2) was also measured transcutaneous. Ventricular fibrillation (VF) was induced and untreated for 10 min. Pigs were randomized to

SUBMITTER: Moore JC 

PROVIDER: S-EPMC7855054 | biostudies-literature | 2021 Jan

REPOSITORIES: biostudies-literature