Displacement Imaging During Focused Ultrasound Median Nerve Modulation: A Preliminary Study in Human Pain Sensation Mitigation.
Ontology highlight
ABSTRACT: Focused ultrasound (FUS)-based viscoelastic imaging techniques using high frame rate (HFR) ultrasound to track tissue displacement can be used for mechanistic monitoring of FUS neuromodulation. However, a majority of techniques avoid imaging during the active push transmit (interleaved or postpush acquisitions) to mitigate ultrasound interference, which leads to missing temporal information of ultrasound effects when FUS is being applied. Furthermore, critical for clinical translation, use of both axial steering and real-time (<1 s) capabilities for optimizing acoustic parameters for tissue engagement are largely missing. In this study, we describe a method of noninterleaved, single Vantage imaging displacement within an active FUS push with simultaneous axial steering and real-time capabi
SUBMITTER: Lee SA
PROVIDER: S-EPMC7858702 | biostudies-literature | 2021 Mar
REPOSITORIES: biostudies-literature
ACCESS DATA