ABSTRACT: Purpose
To compare the likelihood of spiral fracture of the humerus using torsional load to failure after intraosseous biceps tenodesis at the position of the arthroscopic suprapectoral tenodesis versus the subpectoral meta-diaphyseal location.Methods
Eight matched pairs of humeri were dissected. Unicortical tenodesis holes were drilled, either at the bottom of the bicipital groove (group 1) or just below the pectoralis major tendon insertion (subpectoral) in the humeral diaphysis (group 2). Tenodesis was performed in a 7-mm bone tunnel, with suture fixation distal to this site using 2 separate 2-mm holes, secured with No. 2 polyester suture. Each humerus was potted in plaster and mounted to a hydraulic torsional load frame, consistent with previously validated models for c