Unknown

Dataset Information

Hemodynamic effects of high frequency oscillatory ventilation with volume guarantee in a piglet model of respiratory distress syndrome.


ABSTRACT: Respiratory failure is a common condition faced by critically ill neonates with respiratory distress syndrome (RDS). High frequency oscillatory ventilation (HFOV) is often used for neonates with refractory respiratory failure related to RDS. Volume guarantee (VG) mode has been added to some HFOV ventilators for providing consistent tidal volume. We sought to examine the impact of adding the VG mode during HFOV on systemic and cerebral hemodynamics, which has not been studied to date. A neonatal piglet model of moderate to severe RDS was induced by saline lavage. Piglets (full term, age 1-3 days, weight 1.5-2.4 kg) were randomized to have RDS induced and receive either HFOV or HFOV+VG (n = 8/group) or sham-operation (n = 6) without RDS. Cardiac function measured by a Millar® catheter placed

SUBMITTER: Bhogal J 

PROVIDER: S-EPMC7886162 | biostudies-literature | 2021