Comparison of microleakage between different restorative materials to restore marginal gap at crown margin.


ABSTRACT:

Background

An occurrence of secondary caries around the indirect restoration margin is reported to remain a leading cause of failures.

Objective

This study aimed to test the interfacial microleakage of conventional glass-ionomer (CGI), resin-modified glass ionomer (RMGI) and Nano-hybrid composite (CR) restorations at a full veneer margin crown.

Methods

Ninety human extracted molar teeth were divided into three groups (n = 30). Each group was subdivided into three subgroups (n = 10) according to the extent of the structural defects; The structural defect in G1 had a depth of 1.5 mm, width and length at 2 mm and 1 mm intrusion within the crown cervical margin. The corresponding structural defect dimension values for G2 were 2, 5, 4 and 2 mm with defects ex