Multinational evaluation of the BioFire® FilmArray® Pneumonia plus Panel as compared to standard of care testing.
Ontology highlight
ABSTRACT: This study compared standard of care testing (SOC) to BioFire® FilmArray® Pneumonia plus Panel (PNplus). PNplus detects 15 bacteria with semiquantitative log bin values, 7 antibiotic resistance markers, three atypical bacteria (AB), and eight viral classes directly from bronchoalveolar lavage-like specimens (BLS) and sputum-like specimens (SLS). Fifty-two laboratories from 13 European countries and Israel tested 1234 BLS and 1242 SLS with PNplus and SOC. Detection rates and number of pathogens/samples were compared for PNplus pathogens. PNplus bin values and SOC quantities were compared. Three thousand two hundred sixty-two bacteria in PNplus were detected by PNplus and/or SOC. SOC detected 57.1% compared to 95.8% for PNplus (p ≤ 0.0001). PNplus semiquantitative bin values were less than S
SUBMITTER: Ginocchio CC
PROVIDER: S-EPMC7924818 | biostudies-literature | 2021 Aug
REPOSITORIES: biostudies-literature
ACCESS DATA