Artificial intelligence for reduced dose 18F-FDG PET examinations: a real-world deployment through a standardized framework and business case assessment.


ABSTRACT:

Background

To determine whether artificial intelligence (AI) processed PET/CT images of reduced by one-third of 18-F-FDG activity compared to the standard injected dose, were non-inferior to native scans and if so to assess the potential impact of commercialization.

Materials and methods

SubtlePET™ AI was introduced in a PET/CT center in Italy. Eligible patients referred for 18F-FDG PET/CT were prospectively enrolled. Administered 18F-FDG was reduced to two-thirds of standard dose. Patients underwent one low-dose CT and two sequential PET scans; "PET-processed" with reduced dose and standard acquisition time, and "PET-native" with an elapsed time to simulate standard acquisition time and dose. PET-processed images were reconstructed using SubtlePET™. PET-native images were d

SUBMITTER: Katsari K 

PROVIDER: S-EPMC7943690 | biostudies-literature | 2021 Mar