Usefulness of Non-Contrast-Enhanced MR Angiography Using a Silent Scan for Follow-Up after Y-Configuration Stent-Assisted Coil Embolization for Basilar Tip Aneurysms.


ABSTRACT:

Background and purpose

Y-configuration stent-assisted coil embolization is used for treating wide-neck aneurysms. Noninvasive alternatives to x-ray DSA for follow-up after Y-configuration stent-assisted coil embolization treatment are required. This study aimed to assess the usefulness of non-contrast-enhanced MRA by using a Silent Scan (silent MRA) for follow-up after Y-configuration stent-assisted coil embolization for basilar tip aneurysms.

Materials and methods

Seven patients treated with Y-configuration stent-assisted coil embolization for basilar tip aneurysms underwent silent MRA, 3D TOF-MRA, and DSA. Silent MRA and 3D TOF-MRA images were obtained during the same scan session on a 3T MR imaging system. Two neuroradiologists independently reviewed both types of MRA images and subjectively scored the flow in the stents on a scale of 1 (not visible) to 5 (nearly equal to DSA) by referring to the latest DSA image as a criterion standard. Furthermore, we evaluated the visualization of the neck remnant.

Results

In all patients, the 2 observers gave a higher score for the flow in the stents on silent MRA than on 3D TOF-MRA. The average score ± standard deviation was 4.07 ± 0.70 for silent MRA and 1.93 ± 0.80 (P < .05) for 3D TOF-MRA. Neck remnants were depicted by DSA in 5 patients. In silent MRA, neck remnants were depicted in 5 patients, and visualization was similar to DSA; however, in 3D TOF-MRA, neck remnants were depicted in only 1 patient.

Conclusions

Silent MRA might be useful for follow-up after Y-configuration stent-assisted coil embolization.

SUBMITTER: Takano N 

PROVIDER: S-EPMC7959988 | biostudies-literature | 2017 Mar

REPOSITORIES: biostudies-literature

altmetric image

Publications

Usefulness of Non-Contrast-Enhanced MR Angiography Using a Silent Scan for Follow-Up after Y-Configuration Stent-Assisted Coil Embolization for Basilar Tip Aneurysms.

Takano N N   Suzuki M M   Irie R R   Yamamoto M M   Hamasaki N N   Kamagata K K   Kumamaru K K KK   Hori M M   Oishi H H   Aoki S S  

AJNR. American journal of neuroradiology 20161222 3


<h4>Background and purpose</h4>Y-configuration stent-assisted coil embolization is used for treating wide-neck aneurysms. Noninvasive alternatives to x-ray DSA for follow-up after Y-configuration stent-assisted coil embolization treatment are required. This study aimed to assess the usefulness of non-contrast-enhanced MRA by using a Silent Scan (silent MRA) for follow-up after Y-configuration stent-assisted coil embolization for basilar tip aneurysms.<h4>Materials and methods</h4>Seven patients  ...[more]

Similar Datasets

| S-EPMC8814699 | biostudies-literature
| S-EPMC7655352 | biostudies-literature
| S-EPMC5007409 | biostudies-literature
| S-EPMC4882272 | biostudies-literature
| S-EPMC9240056 | biostudies-literature
| S-EPMC11569807 | biostudies-literature
| S-EPMC5416824 | biostudies-literature
| S-EPMC7965868 | biostudies-literature
| S-EPMC4212997 | biostudies-literature
| S-EPMC9026215 | biostudies-literature