Unknown

Dataset Information

Core Alzheimer's disease cerebrospinal fluid biomarker assays are not affected by aspiration or gravity drip extraction methods.


ABSTRACT:

Background

CSF biomarkers are well-established for routine clinical use, yet a paucity of comparative assessment exists regarding CSF extraction methods during lumbar puncture. Here, we compare in detail biomarker profiles in CSF extracted using either gravity drip or aspiration.

Methods

Biomarkers for β-amyloidopathy (Aβ1-42, Aβ1-40), tauopathy (total tau), or synapse pathology (BACE1, Neurogranin Trunc-p75, α-synuclein) were assessed between gravity or aspiration extraction methods in a sub-population of the Australian Imaging, Biomarkers and Lifestyle (AIBL) study (cognitively normal, N = 36; mild cognitive impairment, N = 8; Alzheimer's disease, N = 6).

Results

High biomarker concordance between extraction methods was seen (concordance correlation > 0.85). Passing

SUBMITTER: Doecke JD 

PROVIDER: S-EPMC8052760 | biostudies-literature | 2021 Apr

REPOSITORIES: biostudies-literature