Ontology highlight
ABSTRACT: Introduction
Open reduction and internal fixation (ORIF) of displaced midshaft clavicle fractures is associated with higher union rates and earlier functional recovery. However, ORIF with plate fixation is associated with complications including implant irritation and implant failure. Dual plate fixation provides fixation in orthogonal planes, and uses a lower profile fixation technique in comparison to pre-contoured and surgeon-contoured small-fragment locking plates, which may be more prominent. The objective of this study was to conduct a systematic review to summarize outcomes and complications associated with surgical fixation of displaced acute midshaft clavicle fractures with dual plate fixation.Methods
Using a predetermined study protocol in accordance with the Pref
SUBMITTER: You DZ
PROVIDER: S-EPMC8079453 | biostudies-literature | 2021 Jun
REPOSITORIES: biostudies-literature