Safety and efficacy of an implantable device for management of gastroesophageal reflux in lung transplant recipients.


ABSTRACT:

Background

Magnetic sphincter augmentation (MSA) is a promising minimally invasive surgical technique for management of gastroesophageal reflux disease (GERD); however, device implantation after transplantation has not been studied and may be concerning in these immunosuppressed patients. We explored the safety of the LINX Reflux Management System (MSA device) for management of GERD following lung transplantation (LTx).

Methods

Lung transplant recipients who underwent LINX implantation at our institution between 2017 and 2019 were followed prospectively in the Reflux Following Lung Transplantation and Associated Treatment Registry. Ambulatory pH testing and acid-suppressing medication use were compared before and after LINX implantation. One-year outcomes and change in pulmonary function were compared between matched LINX and fundoplication groups.

Results

Of 17 patients who underwent post-lung transplant LINX implantation, 8 (47.1%) agreed to undergo post-LINX pH testing. Three/eight (37.5%) patients achieved normal esophageal acid exposure time; 14 (82.4%) remained on acid-suppressing medication at one-year under the direction of their transplant teams. One-year patient survival and change in pulmonary function were similar between groups. LINX patients experienced more early side effects.

Conclusions

Use of the LINX MSA device in a cohort of lung transplant recipients at our institution was associated with similar short-term safety compared to traditional fundoplication, however assessment of efficacy was limited. Further investigation is needed to characterize the long-term efficacy of LINX implantation after LTx.

SUBMITTER: Halpern SE 

PROVIDER: S-EPMC8107527 | biostudies-literature | 2021 Apr

REPOSITORIES: biostudies-literature

altmetric image

Publications

Safety and efficacy of an implantable device for management of gastroesophageal reflux in lung transplant recipients.

Halpern Samantha E SE   Gupta Aryaman A   Jawitz Oliver K OK   Choi Ashley Y AY   Salfity Hai V HV   Klapper Jacob A JA   Hartwig Matthew G MG  

Journal of thoracic disease 20210401 4


<h4>Background</h4>Magnetic sphincter augmentation (MSA) is a promising minimally invasive surgical technique for management of gastroesophageal reflux disease (GERD); however, device implantation after transplantation has not been studied and may be concerning in these immunosuppressed patients. We explored the safety of the LINX Reflux Management System (MSA device) for management of GERD following lung transplantation (LTx).<h4>Methods</h4>Lung transplant recipients who underwent LINX implant  ...[more]

Similar Datasets

| S-EPMC11666770 | biostudies-literature
| S-EPMC11018667 | biostudies-literature
| S-EPMC8986733 | biostudies-literature
| S-EPMC9303339 | biostudies-literature
| S-EPMC10403642 | biostudies-literature
| S-EPMC7483994 | biostudies-literature
| S-EPMC3662205 | biostudies-other
| S-EPMC8670859 | biostudies-literature
| S-EPMC11320289 | biostudies-literature
| S-EPMC4518147 | biostudies-literature