Clinical characterization of respiratory large droplet production during common airway procedures using high-speed imaging.
Ontology highlight
ABSTRACT: During the COVID-19 pandemic, a significant number of healthcare workers have been infected with SARS-CoV-2. However, there remains little knowledge regarding large droplet dissemination during airway management procedures in real life settings. 12 different airway management procedures were investigated during routine clinical care. A high-speed video camera (1000 frames/second) was for imaging. Quantitative droplet characteristics as size, distance traveled, and velocity were computed. Droplets were detected in 8/12 procedures. The droplet trajectories could be divided into two distinctive patterns (type 1/2). Type 1 represented a ballistic trajectory with higher speed large droplets whereas type 2 represented a random trajectory of slower particles that persisted longer in air. The use
SUBMITTER: Mueller SK
PROVIDER: S-EPMC8137881 | biostudies-literature | 2021 May
REPOSITORIES: biostudies-literature
ACCESS DATA