Quantification of 17 Endogenous and Exogenous Steroidal Hormones in Equine and Bovine Blood for Doping Control with UHPLC-MS/MS.
Ontology highlight
ABSTRACT: A simple and fast analytical method able to simultaneously identify and quantify 17 endogenous and exogenous steroidal hormones was developed in bovine and equine blood using UHPLC-MS/MS. A total amount of 500 µL of sample was deproteinized with 500 µL of a mixture of methanol and zinc sulfate and evaporated. The mixture was reconstituted with 50 µL of a solution of 25% methanol and injected in the UHPLC-MS/MS triple quadrupole. The correlation coefficients of the calibration curves of the analyzed compounds were in the range of 0.9932-0.9999, and the limits of detection and quantification were in the range of 0.023-1.833 and 0.069-5.5 ppb, respectively. The developed method showed a high sensitivity and qualitative aspects allowing the detection and quantification of all steroids in equin
SUBMITTER: Caprioli G
PROVIDER: S-EPMC8143330 | biostudies-literature | 2021 Apr
REPOSITORIES: biostudies-literature