Temporal Incidence and Predictors of High-Grade Atrioventricular Block After Transcatheter Aortic Valve Replacement.
Ontology highlight
ABSTRACT: Background The temporal incidence of high-grade atrioventricular block (HAVB) after transcatheter aortic valve replacement (TAVR) is uncertain. As a result, periprocedural monitoring and pacing strategies remain controversial. This study aimed to describe the temporal incidence of initial episode of HAVB stratified by pre- and post-TAVR conduction and identify predictors of delayed events. Methods and Results Consecutive patients undergoing TAVR at a single center between February 2012 and June 2019 were retrospectively assessed for HAVB within 30 days. Patients with prior aortic valve replacement, permanent pacemaker (PPM), or conversion to surgical replacement were excluded. Multivariable logistic regression was performed to assess predictors of delayed HAVB (initial event >24 hours post
SUBMITTER: El-Sabawi B
PROVIDER: S-EPMC8200694 | biostudies-literature | 2021 May
REPOSITORIES: biostudies-literature
ACCESS DATA