Ontology highlight
ABSTRACT: Background
125I seed implantation has been found to show good therapeutic effects on tumors. Recent studies showed that three-dimensional (3D) print template-assisted 125I seed implantation can optimize radiation dose distribution. This study aimed to compare the dose distribution differences in 125I seed implantation among 3D print noncoplanar template- (3DPNCT), 3D print coplanar template- (3DPCT) assisted implantation and traditional free-hand implantation.Methods
We systematically searched the PubMed, EMbase, Cochrane Library, Wan Fang Med Online, China National Knowledge Infrastructure (CNKI) from the earliest to November 2020 without time or language restrictions. And the references of primary literature were also searched. The outcome
SUBMITTER: Chen E
PROVIDER: S-EPMC8223396 | biostudies-literature | 2021 Jun
REPOSITORIES: biostudies-literature