AutoFlow® versus volume-controlled ventilation for laparoscopic gynecological surgery using LMA® ProSeal™: a randomized controlled trial.


ABSTRACT:

Background

During laparoscopic gynecological surgery, increased peak airway pressure (PAWP) can cause airway leak upon ventilation with the LMA® ProSeal™. We hypothesized that compared with the use of volume-controlled ventilation (VCV), the use of the AutoFlow® mode would decrease PAWP and airway leak during laparoscopic gynecological surgery with LMA ProSeal.

Methods

This single-center, randomized, controlled trial allocated 80 adult women undergoing elective laparoscopic gynecological surgery to one of two groups, namely, the AutoFlow group or the VCV group. Ventilation settings for both groups were 8 ml/kg of tidal volume and 5 cmH2O of positive end-expiratory pressure, and respiratory rate was adjusted to maintain end-tidal carbon dioxide at 35-40 mmHg. Airwa