Critical Design Parameters in Design and Efficacy of Upper-Room UVC254 Luminaire Systems: Part I: Overview of Major Parameters and Relationships†.


ABSTRACT: During the current SARS-CoV-2 and tuberculosis global pandemics, public health and infection prevention and control professionals wrestle with cost-effective means to control airborne transmission. One technology recommended by Centers for Disease Control and Prevention and the World Health Organization for lowering indoor concentration of these and other microorganisms and viruses is upper-room ultraviolet 254 nm (UVC254 ) systems. Applying both a material balance as well as some nondimensional parameters developed by Rudnick and First, the impact of several critical parameters and their effect on the fraction of microorganisms surviving UVC254 exposure was evaluated. Vertical airspeed showed a large impact at velocities <0.05 m s-1 but a lesser effect at