Unknown

Dataset Information

Rapid SARS-CoV-2 variant monitoring using PCR confirmed by whole genome sequencing in a high-volume diagnostic laboratory.


ABSTRACT:

Objectives

The emerging SARS-CoV-2 variants of concern (VoC), B.1.1.7, B.1.351 and P.1, with increased transmission and/or immune evasion, emphasise the need for broad and rapid variant monitoring. Our high-volume laboratory introduced a PCR variant assay (Variant PCR) in January 2021 based on the protocol by Vogels et al. STUDY DESIGN: To assess whether Variant PCR could be used for rapid B.1.1.7, B.1.351 and P.1 screening, all positive SARS-CoV-2 airway samples were prospectively tested in parallel using both the Variant PCR and whole genome sequencing (WGS).

Results

In total 1,642 SARS-CoV-2 positive samples from individual patients were tested within a time span of 4 weeks. For all samples with valid results from both Variant PCR and WGS, no VoC was missed by Variant PCR

SUBMITTER: Lind A 

PROVIDER: S-EPMC8262397 | biostudies-literature | 2021 Aug

REPOSITORIES: biostudies-literature