Unknown

Dataset Information

0

Development of NIR-II Photoacoustic Probes Tailored for Deep-Tissue Sensing of Nitric Oxide.


ABSTRACT: Photoacoustic (PA) imaging has emerged as a reliable in vivo technique for diverse biomedical applications ranging from disease screening to analyte sensing. Most contemporary PA imaging agents employ NIR-I light (650-900 nm) to generate an ultrasound signal; however, there is significant interference from endogenous biomolecules such as hemoglobin that are PA active in this window. Transitioning to longer excitation wavelengths (i.e., NIR-II) reduces the background and facilitates the detection of low abundance targets (e.g., nitric oxide, NO). In this study, we employed a two-phase tuning approach to develop APNO-1080, a NIR-II NO-responsive probe for deep-tissue PA imaging. First, we performed Hammett and Brønsted analyses to identify a highly reactive and selective aniline-based trigger that reacts with NO via N-nitrosation chemistry. Next, we screened a panel of NIR-II platforms to identify chemical structures that have a low propensity to aggregate since this can diminish the PA signal. In a head-to-head comparison with a NIR-I analogue, APNO-1080 was 17.7-fold more sensitive in an in vitro tissue phantom assay. To evaluate the deep-tissue imaging capabilities of APNO-1080 in vivo, we performed PA imaging in an orthotopic breast cancer model and a heterotopic lung cancer model. Relative to control mice not bearing tumors, the normalized turn-on response was 1.3 ± 0.12 and 1.65 ± 0.07, respectively.

SUBMITTER: Lucero MY 

PROVIDER: S-EPMC8274393 | biostudies-literature | 2021 May

REPOSITORIES: biostudies-literature

altmetric image

Publications

Development of NIR-II Photoacoustic Probes Tailored for Deep-Tissue Sensing of Nitric Oxide.

Lucero Melissa Y MY   East Amanda K AK   Reinhardt Christopher J CJ   Sedgwick Adam C AC   Su Shengzhang S   Lee Michael C MC   Chan Jefferson J  

Journal of the American Chemical Society 20210427 18


Photoacoustic (PA) imaging has emerged as a reliable <i>in vivo</i> technique for diverse biomedical applications ranging from disease screening to analyte sensing. Most contemporary PA imaging agents employ NIR-I light (650-900 nm) to generate an ultrasound signal; however, there is significant interference from endogenous biomolecules such as hemoglobin that are PA active in this window. Transitioning to longer excitation wavelengths (i.e., NIR-II) reduces the background and facilitates the de  ...[more]

Similar Datasets

| S-EPMC6020528 | biostudies-literature
| S-EPMC8917156 | biostudies-literature
| S-EPMC7533907 | biostudies-literature
| S-EPMC6773519 | biostudies-literature
| S-EPMC10638547 | biostudies-literature
| S-EPMC7331458 | biostudies-literature
| S-EPMC3872128 | biostudies-literature
| S-EPMC9661837 | biostudies-literature
| S-EPMC9686608 | biostudies-literature
| S-EPMC7856908 | biostudies-literature