Effects of intracorneal ring segments implementation technique and design on corneal biomechanics and keratometry in a personalized computational analysis.
Ontology highlight
ABSTRACT: The implementation of intracorneal ring segments (ICRS) is one of the successfully applied refractive operations for the treatment of keratoconus (kc) progression. The different selection of ICRS types along with the surgical implementation techniques can significantly affect surgical outcomes. Thus, this study aimed to investigate the influence of ICRS implementation techniques and design on the postoperative biomechanical state and keratometry results. The clinical data of three patients with different stages and patterns of keratoconus were assessed to develop a three-dimensional (3D) patient-specific finite-element model (FEM) of the keratoconic cornea. For each patient, the exact surgery procedure definitions were interpreted in the step-by-step FEM. Then, seven surgical scenarios, in
SUBMITTER: Bagheri NM
PROVIDER: S-EPMC8277910 | biostudies-literature | 2021 Jul
REPOSITORIES: biostudies-literature
ACCESS DATA