Unknown

Dataset Information

0

Pretreatment central quality control for craniospinal irradiation in non-metastatic medulloblastoma : First experiences of the German radiotherapy quality control panel in the SIOP PNET5 MB trial.


ABSTRACT:

Purpose

Several studies have demonstrated the negative impact of radiotherapy protocol deviations on tumor control in medulloblastoma. In the SIOP PNET5 MB trial, a pretreatment radiotherapy quality control (RT-QC) program was introduced. A first analysis for patients enrolled in Germany, Switzerland and Austria with focus on types of deviations in the initial plan proposals and review criteria for modern radiation technologies was performed.

Methods and patients

Sixty-nine craniospinal irradiation (CSI) plans were available for detailed analyses. RT-QC was performed according to protocol definitions on dose uniformity. Because of the lack of definitions for high-precision 3D conformal radiotherapy within the protocol, additional criteria for RT-QC on delineation and coverage of clinical target volume (CTV) and planning target volume (PTV) were defined and evaluated.

Results

Target volume (CTV/PTV) deviations occurred in 49.3% of initial CSI plan proposals (33.3% minor, 15.9% major). Dose uniformity deviations were less frequent (43.5%). Modification of the RT plan was recommended in 43.5% of CSI plans. Unacceptable RT plans were predominantly related to incorrect target delineation rather than dose uniformity. Unacceptable plans were negatively correlated to the number of enrolled patients per institution with a cutoff of 5 patients (p = 0.001).

Conclusion

This prospective pretreatment individual case review study revealed a high rate of deviations and emphasizes the strong need of pretreatment RT-QC in clinical trials for medulloblastoma. Furthermore, the experiences point out the necessity of new RT-QC criteria for high-precision CSI techniques.

SUBMITTER: Dietzsch S 

PROVIDER: S-EPMC8292275 | biostudies-literature | 2021 Aug

REPOSITORIES: biostudies-literature

altmetric image

Publications

Pretreatment central quality control for craniospinal irradiation in non-metastatic medulloblastoma : First experiences of the German radiotherapy quality control panel in the SIOP PNET5 MB trial.

Dietzsch Stefan S   Braesigk Annett A   Seidel Clemens C   Remmele Julia J   Kitzing Ralf R   Schlender Tina T   Mynarek Martin M   Geismar Dirk D   Jablonska Karolina K   Schwarz Rudolf R   Pazos Montserrat M   Walser Marc M   Frick Silke S   Gurtner Kristin K   Matuschek Christiane C   Harrabi Semi Ben SB   Glück Albrecht A   Lewitzki Victor V   Dieckmann Karin K   Benesch Martin M   Gerber Nicolas U NU   Rutkowski Stefan S   Timmermann Beate B   Kortmann Rolf-Dieter RD  

Strahlentherapie und Onkologie : Organ der Deutschen Rontgengesellschaft ... [et al] 20201123 8


<h4>Purpose</h4>Several studies have demonstrated the negative impact of radiotherapy protocol deviations on tumor control in medulloblastoma. In the SIOP PNET5 MB trial, a pretreatment radiotherapy quality control (RT-QC) program was introduced. A first analysis for patients enrolled in Germany, Switzerland and Austria with focus on types of deviations in the initial plan proposals and review criteria for modern radiation technologies was performed.<h4>Methods and patients</h4>Sixty-nine cranio  ...[more]

Similar Datasets

| S-EPMC8863746 | biostudies-literature
| S-EPMC8773789 | biostudies-literature
| S-EPMC6421074 | biostudies-literature
| S-EPMC10976906 | biostudies-literature
| S-EPMC8443797 | biostudies-literature
| S-EPMC7643335 | biostudies-literature
| S-EPMC8657236 | biostudies-literature
| S-EPMC5514252 | biostudies-other
| S-EPMC11039907 | biostudies-literature
| S-EPMC4657242 | biostudies-other