Ontology highlight
ABSTRACT:
SUBMITTER: Altinkurt E
PROVIDER: S-EPMC8302312 | biostudies-literature | 2021 Jun
REPOSITORIES: biostudies-literature
Altinkurt Emre E Sayar Bilgin Gizem G
Indian journal of ophthalmology 20210601 6
The procedure involved an ab-externo scleral fixation technique using a double-armed 10-0 polypropylene suture with straight needles that require no scleral flaps. The IOLs are sutured to the sclera, the free suture ends are tied to the suture loops, and they are buried together under the sclera. Forty eyes of 37 patients were included. Postoperative complications are IOL capture in five eyes (12.5%), a significant IOL tilt in one eye (2.5%), recurrent UGH (uveitis-glaucoma-hyphema) syndrome in ...[more]