Unknown

Dataset Information

Observation of Conditions Preceding Peak Indoor Air Volatile Org Compound Concentrations in Vapor Intrusion Studies.


ABSTRACT: Temporal and spatial variability of indoor air volatile organic compound (VOC) concentrations can complicate vapor intrusion (VI) assessment and decision-making. Indicators and tracers (I&T) of VI, such as differential temperature, differential pressure, and indoor radon concentration, are low-cost lines of evidence to support sampling scheduling and interpretation of indoor air VOC sampling results. This study compares peak indoor air chlorinated VOC concentrations and I&T conditions before and during those peak events at five VI sites. The sites differ geographically and in their VI conceptual site models (CSM). Relative to site-specific baseline values, the results show that cold or falling outdoor temperatures, rising cross slab differential pressures, and increasing indoor radon conce

SUBMITTER: Lutes C 

PROVIDER: S-EPMC8318117 | biostudies-literature | 2021 May