Unknown

Dataset Information

0

Trans-apical aortic valve implantation for quadricuspid aortic valve with aortic regurgitation using J-valve system: a case reports.


ABSTRACT:

Background

Quadricuspid aortic valve (QAV) is a rare congenital heart defect usually accompanied with different hemodynamic abnormalities. Due to the rarity of QAV, treatment and prognosis of QAV patients with aortic regurgitation still remain challenging. We here present the first case of a patient with severe QAV regurgitation who underwent successful treatment and performed favorable prognosis with transapical aortic valve implantation (TAVI) using J-Valve system.

Case presentation

A 62-year-old man experienced intermittent palpitation, shortness of breath and chest pain. Echocardiography revealed congenital QAV with massive aortic regurgitation and mild aortic stenosis, left ventricular enlargement. Aortic valve replacement was successfully performed with TAVI using J-Valve system. The postoperation and follow-up was uneventful.

Conclusion

TAVI using J-Valve system has emerged as a new high success rate method for treatment of patients with simple non-calcified aortic valve insufficiency.

SUBMITTER: Luo C 

PROVIDER: S-EPMC8330120 | biostudies-literature | 2021 Aug

REPOSITORIES: biostudies-literature

altmetric image

Publications

Trans-apical aortic valve implantation for quadricuspid aortic valve with aortic regurgitation using J-valve system: a case reports.

Luo Chaodi C   Jiang Yi Y   Chen Qiang Q   Yan Yang Y   Han Dan D  

Journal of cardiothoracic surgery 20210803 1


<h4>Background</h4>Quadricuspid aortic valve (QAV) is a rare congenital heart defect usually accompanied with different hemodynamic abnormalities. Due to the rarity of QAV, treatment and prognosis of QAV patients with aortic regurgitation still remain challenging. We here present the first case of a patient with severe QAV regurgitation who underwent successful treatment and performed favorable prognosis with transapical aortic valve implantation (TAVI) using J-Valve system.<h4>Case presentation  ...[more]

Similar Datasets

| S-EPMC7451882 | biostudies-literature
| S-EPMC3325860 | biostudies-literature
| S-EPMC11886369 | biostudies-literature
| S-EPMC3957461 | biostudies-literature
| S-EPMC9024092 | biostudies-literature
| S-EPMC10201900 | biostudies-literature
| S-EPMC8564067 | biostudies-literature
| S-EPMC5361996 | biostudies-other
| S-EPMC11303856 | biostudies-literature
| S-EPMC5385316 | biostudies-literature