Unknown

Dataset Information

Resorbable vascular grafts show rapid cellularization and degradation in the ovine carotid.


ABSTRACT: Small-diameter vascular grafts perform poorly as arterial bypasses. We developed a cell-free, resorbable graft intended to remodel in situ into a living vessel. The graft consisted of a soft electrospun poly(glycerol sebacate) (PGS) core, a PGS prepolymer (pPGS) coating, and a reinforcing electrospun poly(ε-caprolactone) (PCL) sheath. The core contained 4.37 ± 1.95 μm fibers and had a porosity of 66.4 ± 3.2%, giving it large pores to encourage cellular infiltration and pro-healing macrophages. The sheath contained 6.63 ± 0.89 μm fibers and had a porosity of 80.5 ± 2.1%. in vitro testing suggested that the stress achieved at arterial pressure would be 13-fold lower than the yield stress of the graft. Grafts were implanted as 7 cm carotid interpositions in two sheep. Sheep were maintained on

SUBMITTER: Stowell CET 

PROVIDER: S-EPMC8351370 | biostudies-literature | 2020 Nov

REPOSITORIES: biostudies-literature