Unknown

Dataset Information

Fully automated closed-loop glucose control compared with standard insulin therapy in adults with type 2 diabetes requiring dialysis: an open-label, randomized crossover trial.


ABSTRACT: We evaluated the safety and efficacy of fully closed-loop insulin therapy compared with standard insulin therapy in adults with type 2 diabetes requiring dialysis. In an open-label, multinational, two-center, randomized crossover trial, 26 adults with type 2 diabetes requiring dialysis (17 men, 9 women, average age 68 ± 11 years (mean ± s.d.), diabetes duration of 20 ± 10 years) underwent two 20-day periods of unrestricted living, comparing the Cambridge fully closed-loop system using faster insulin aspart ('closed-loop') with standard insulin therapy and a masked continuous glucose monitor ('control') in random order. The primary endpoint was time in target glucose range (5.6-10.0 mmol l-1). Thirteen participants received closed-loop first and thirteen received control therapy

SUBMITTER: Boughton CK 

PROVIDER: S-EPMC8363503 | biostudies-literature | 2021 Aug

REPOSITORIES: biostudies-literature