Bronchial rupture following endobronchial blocker placement: a case report of a rare, unfortunate complication.


ABSTRACT:

Background

Lung separation may be achieved through the use of double lumen tubes or endobronchial blockers. The use of lung separation techniques carries the risk of airway injuries which range from minor complications like postoperative hoarseness and sore throat to rare and potentially devastating tracheobronchial mucosal injuries like bronchus perforation or rupture. With few case reports to date, bronchial rupture with the use of endobronchial blockers is indeed an overlooked complication.

Case presentation

A 78-year-old male patient with a left upper lobe lung adenocarcinoma underwent a left upper lobectomy with a Fuji Uniblocker® as the lung separation device. Despite an atraumatic insertion and endobronchial blocker balloon volume within manufacturer specifications, an intraoperative air leak developed, and the patient was found to have sustained a left mainstem bronchus rupture which was successfully repaired and the patient extubated uneventfully. Unfortunately, the patient passed on in-hospital from sepsis and other complications.

Conclusion

Bronchial rupture is a serious complication of endobronchial blocker use that can carry significant morbidity, and due care should be exercised in its use and placement. Bronchoscopy should be used during insertion, and the volume and pressure of the balloon kept to the minimum required to prevent air leak. Bronchial injury should be considered as a differential in the presence of an unexplained air leak.

SUBMITTER: Oo S 

PROVIDER: S-EPMC8404020 | biostudies-literature | 2021 Aug

REPOSITORIES: biostudies-literature

altmetric image

Publications

Bronchial rupture following endobronchial blocker placement: a case report of a rare, unfortunate complication.

Oo Shuwen S   Chia Rachel Hui Xuan RHX   Li Yue Y   Sampath Hari Kumar HK   Ang Sophia Bee Leng SBL   Paranjothy Suresh S   Tam John Kit Chung JKC   Lee Chang Chuan Melvin CCM  

BMC anesthesiology 20210830 1


<h4>Background</h4>Lung separation may be achieved through the use of double lumen tubes or endobronchial blockers. The use of lung separation techniques carries the risk of airway injuries which range from minor complications like postoperative hoarseness and sore throat to rare and potentially devastating tracheobronchial mucosal injuries like bronchus perforation or rupture. With few case reports to date, bronchial rupture with the use of endobronchial blockers is indeed an overlooked complic  ...[more]

Similar Datasets

| S-EPMC9676440 | biostudies-literature
| S-EPMC8665675 | biostudies-literature
| S-EPMC8193112 | biostudies-literature
| S-EPMC6683213 | biostudies-literature
| S-EPMC9341070 | biostudies-literature
| S-EPMC5956624 | biostudies-literature
| S-EPMC8039777 | biostudies-literature
| S-EPMC11459450 | biostudies-literature
| S-EPMC6926249 | biostudies-literature
| S-EPMC7431483 | biostudies-literature