ABSTRACT: Background
Femoral cannulation is commonly used in minimally invasive cardiac surgery to establish extracorporeal circulation. We present a case with a finding that should be evaluated when screening candidates for minimally invasive cardiac surgery.Case summary
A 57-year-old male patient was scheduled for minimally invasive repair of the mitral and tricuspid valve and a MAZE procedure. During surgery there was difficulty advancing the venous cannula inserted in the right femoral vein. On transoesophageal echocardiography a guidewire advanced from the femoral vein was observed entering the right atrium from the superior vena cava. Despite inserting a second venous cannula in the jugular vein, venous drainage was insufficient for minimal invasive surgery. The approach was co